AKT1 ligand-1
AKT1 ligand-1 is an AKT1 ligand. AKT1 ligand-1 exhibits anticancer activity against prostate cancer, lung cancer, and breast cancer.
For research use only. We do not sell to patients.
- Formula: C21H23ClN4O2S
- Molecular Weight:430.95
-
Storage:
Please store the product under the recommended conditions in the Certificate of Analysis.
Biological Activity
Description
IC50 & Target
[1]|
Akt1 |
Cellular Effect
|
Cell Line
|
Type | Value | Description | References |
|---|---|---|---|---|
| PC-3 | IC50 |
16.12 μM
|
Cytotoxicity against human PC3 prostate adenocarcinoma cells measured by MTT assay after 24 hrs incubation.
Cytotoxicity against human PC3 prostate adenocarcinoma cells measured by MTT assay after 24 hrs incubation.
|
s41598-026-67079-8 |
| A549 | IC50 |
26.36 μM
|
Cytotoxicity against human A549 lung carcinoma cells measured by MTT assay after 24 hrs incubation.
Cytotoxicity against human A549 lung carcinoma cells measured by MTT assay after 24 hrs incubation.
|
s41598-026-67079-8 |
| MCF7 | IC50 |
19.12 μM
|
Cytotoxicity against human MCF-7 breast adenocarcinoma cells measured by MTT assay after 24 hrs incubation.
Cytotoxicity against human MCF-7 breast adenocarcinoma cells measured by MTT assay after 24 hrs incubation.
|
s41598-026-67079-8 |
In Vitro
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
-
Cell Line:PC3, A549, and MCF-7 human cancer cell lines
-
Concentration:6.25-100 µM
-
Incubation Time:24 h
-
Result:IC50 values for AKT1 ligand-1 (compound 4b) were 16.12 µM against PC3, 26.36 µM against A549, and 19.12 µM against MCF-7.
AKT1 ligand-1 (compound 4b) showed 1.6-fold higher potency against PC3 compared with A549.
Chemical Information
-
Molecular Weight 430.95
-
Formula C21H23ClN4O2S
-
SMILES
C=C([C@@H]1CC=C(/C(C1)=N/N=C2SC(C(OCC)=O)=NN/2C3=CC=C(C=C3)Cl)C)C
-
Shipping
Room temperature in continental US; may vary elsewhere.
-
Storage
Please store the product under the recommended conditions in the Certificate of Analysis.
Purity & Documentation
References
Calculators
Concentration (start) × Volume (start) = Concentration (final) × Volume (final)